A study on degree-day regions of Turkey
Küçük Resim Yok
Tarih
2016
Yazarlar
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Springer Netherlands
Erişim Hakkı
info:eu-repo/semantics/closedAccess
Özet
In Turkey, four degree-day regions stated in the standards are used in building heating energy load calculations. Deficiencies about the degree-day regions are mentioned in some other studies. In this paper, a different climatic zone approach suggested by International Energy Agency (IEA) regarding both heating and cooling degree-day data, derived from Typical Meteorological Year (TMY) data, is used. Results are presented graphically and compared with the current regulations. The second degree-day region, according to Turkish Standard (Thermal Insulation Requirements for Buildings (TS 825)), is divided into four climatic zones with the method proposed by IEA. Difference between monthly outdoor temperature values of the second degree-day region and cities in this region is up to 6.4 °C which is high. The conclusion of this study is that the climatic variables should be evaluated in detail, and a new climatic zone study should be done regarding both heating and cooling loads. This will imply new building energy load calculations for all cities in Turkey. © 2015, Springer Science+Business Media Dordrecht.
Açıklama
Anahtar Kelimeler
Climatic zone, Cooling, Degree-day, Degree-day region, Degree-hour, Heating
Kaynak
Energy Efficiency
WoS Q Değeri
Q3
Scopus Q Değeri
N/A
Cilt
9
Sayı
2